You Save:
Inclusive of all taxes
Product not available
SPECIFICATION IS:7098/PART-1/1988 ,IS 8130/1984,IS 5831 WITH LATEST AMENDMENTS &THIS DATASHEET
OPERATING VOLTAGE 1100 V
PERMISSIBLE VARIATION VOLTAGE & FREQUENCY ±10 %
CONDUCTOR DETAIL CONDUCTOR DETAIL
MATERIAL H2 GRADE ALUMINIUM WIRE (CLASS-2) ASPER IS 8130/1984
SIZE SQMM (MAIN&NEUTRAL) 150
SHAPE OF CONDUCTOR STRANDED & SHAPED
CONDUCTOR RESISTANCE OHM/KM (MAX) AT 20 ⁰C (MAIN&NEUTRAL) 0.206
CONDUCTOR RESISTANCE OHM/KM (MAX) AT 90 ⁰C (MAIN&NEUTRAL) 0.264
INSULATION INSULATION
MATERIAL XLPE COMPOUND AS PER IS 7098/1988
THICKNESS NOM. MM (MAIN&NEUTRAL) 1.40
THICKNESS MIN. MM (MAIN&NEUTRAL) 1.16
COLOUR OF CORE RED, YELLOW , BLUE & BLACK
INNER SHEATH
MATERIAL EXTRUDED PVC TYPE ST-2 COMPOUND
THICKNESS OF INNER SHEATH (MM /MIN ) 0.5
COLOUR OF INNER SHEATH BLACK
ARMOURING ARMOURING
MATERIAL GALVANIZED STEEL STRIP
DIMENSION MM. 4.0X0.80MM+/-10 %
OUTER SHEATH OUTER SHEATH
MATERIAL EXTRUDED PVC TYPE ST-2 COMPOUND
THICKNESS OF OUTER SHEATH (NOMINAL) MM NA
THICKNESS OF OUTER SHEATH (MIN) MM 1.88
COLOUR OF SHEATH BLACK
OVERELL DIAMETER OF CABLE (+/-2.0 MM) 43
MAKE AURAFLEX
Country Of Origin : India
STANDARD LENGTH (±5%) 500 (mtr)
PACKING NON REFUNDABLE WOODEN DRUMS IS:10418/82
MIN. VOLUME RESISTIVITY (MIN) 1 x 1014 Ω-CM AT 27 oC & 1 x 1012 Ω-CM AT 90 oC
HIGH VOLTAGE TEST 3 KV (rms) FOR 5 MINUTES FOR EACH CONNECTION
MINIMUM BENDING RADIUS 12 X D
MAXIMUM OPERATING TEMP. 90 ⁰C
MAXIMUM CONDUCTOR TEMPERATURE DURING SHORT CIRCUIT 250 ⁰C
CURRENT RATING
IN GROUND 249
IN AIR 284
SHORT CIRCUIT CURRENT RATING FOR 1 SEC. DURATION 14.2
CABLE CODE A2XFY
The 4CX150SQMM XLPE/PVC AL Conductor Armoured Cable from AURAFLEX is a high-quality electrical cable designed for various demanding electrical and industrial applications. Conforming to the specifications and guidelines set forth in IS 7098, IS 8130, and IS 5831, this cable incorporates cutting-edge engineering and materials to ensure reliable performance and durability.
With an operating voltage rating of up to 1100 volts and a permissible variation in voltage and frequency of ±10%, this armoured cable is well-suited for a wide range of electrical installations, both underground and in air, where protection against mechanical stress, environmental impacts, and electrical interference is paramount.
The cable is constructed using H2 grade aluminum wire for the conductor, which meets Class-2 standards as per IS 8130/1984, and features a cross-section size of 150 sqmm. Designed for enhanced conductivity, mechanical strength, and resistance to environmental factors, the 4CX150SQMM cable incorporates superior insulation materials and a carefully constructed armouring system.
Material: - H2 Grade Aluminum Wire (Class-2) as per IS 8130/1984
Size: - 150 sqmm for both main and neutral
Shape: - Stranded and shaped
Electrical Resistance: - Max Resistance at 20 ⁰C: 0.206 Ohm/KM - Max Resistance at 90 ⁰C: 0.264 Ohm/KM
Material: - XLPE Compound as per IS 7098/1988
Thickness: - Nominal: 1.40 mm for both main and neutral - Minimum: 1.16 mm for both main and neutral
Colour of Core: - Red, Yellow, Blue, and Black
Material: - Extruded PVC Type ST-2 Compound
Thickness: - Minimum: 0.5 mm
Colour: - Black
Material: - Galvanized Steel Strip
Dimension: - 4.0 x 0.80 mm ± 10%
Material: - Extruded PVC Type ST-2 Compound
Thickness: - Minimum: 1.88 mm
Colour: - Black
Overall Diameter: - +/- 2.0 mm tolerance: 43 mm
Standard Length: - 500 meters ± 5%
Packing: - Non-refundable wooden drums as per IS: 10418/82
Volume Resistivity: - At 27 ⁰C: 1 x 10^14 Ω-CM - At 90 ⁰C: 1 x 10^12 Ω-CM
High Voltage Test: - 3 KV (rms) for 5 minutes for each connection
Minimum Bending Radius: - 12 x Diameter (D)
Maximum Operating Temperature: - 90 ⁰C
Maximum Conductor Temperature During Short Circuit: - 250 ⁰C
Current Rating: - In Ground: 249 A - In Air: 284 A
Short Circuit Current Rating for 1 Second Duration: - 14.2 kA
Cable Code: - A2XFY
The AURAFLEX 4CX150SQMM XLPE/PVC AL Conductor Armoured Cable is manufactured to deliver exceptional performance and reliability in various electrical installations. Its design adheres strictly to the latest amendments in IS 7098/1988, IS 8130/1984, and IS 5831 standards, ensuring a product that meets rigorous national and international benchmarks.
Key Features:
The cable utilizes H2 grade aluminum wire that provides excellent conductivity and mechanical durability. The strands are carefully shaped and stranded to minimize resistance and maximize efficiency.
Insulation Excellence:
Insulated with an XLPE (Cross-Linked Polyethylene) compound, the cable offers high resistance to heat, environmental stress, and chemical interactions. This material ensures longevity and consistent performance.
Protection with Armouring:
The galvanized steel strip armouring provides indispensable protection against physical damage, making the cable suitable for subterranean installations and other environments where the cable might be subject to mechanical stress.
Inner and Outer Sheath: