The SF6 Interrupter Pole 1250A 11KV is the ideal solution for medium voltage switchgear applications, designed to offer reliable and efficient operation under high electrical stress conditions. With a rated voltage of 12KV and a current rating of 1250A, this interrupter pole is engineered specifically for durability and performance in demanding environments. Featuring advanced SF6 gas technology, it utilizes a gas-insulated switchgear design that significantly enhances operational safety and reliability. The SF6 gas acts as both an insulator and an arc-extinguishing medium, ensuring minimal risk of electrical failure. This interrupter pole is built to withstand short circuit currents of up to 40KA for 3 seconds, ensuring your system remains operational even under fault conditions. Its design effectively allows for a longer life span of contact components by controlling the sequence of interruptions, thus optimizing the lifecycle of your electrical installations.
Key Features
Features | Description |
---|---|
Rated Voltage | 12KV |
Rated Current | 1250/2500/3150A |
Rated Frequency | 50Hz |
Short Time Withstand Current | 40KA |
Duration of Short Circuit | 3 seconds |
SF6 Gas Pressure at 20°C | 2.5 bar |
Arc Extinguishing Method | Gas puff extinguishes arc during contact breaking |
Operational Mechanism | Piston movement compresses gas for effective contact separation |
Attributes | Description |
---|---|
Type | Interrupter Pole |
Installation | Indoor / Outdoor |
Material | Aluminum & SF6 |
Safety Class | Insulated and Arc Extinguishing |
Weight | Varies based on configuration |
Certifications | IEC 62271-100 |
Dimensions (L×W×H) | Customizable |
Key Words
*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.
Brand: Heatex
Country Of Origin: India
SF-6 Interrupter Pole
Rated Voltage- 12KV
Rated Current- 1250/2500/3150A
Rated Frequency- 50Hz
Rated Short Time Withstand Current- 40KA
Rated Duration of Short Circuit- 3sec
Rated SF6 gas pressure at 20 deg C- 2.5bar
Operational Features :
1) During breaking of the contacts, the puff of gas extinguishes the arc when the circuit breaker is in the closed position.
2) Due to movement of the piston, the gas is compressed. Firstly, the main contacts open and then the arcing contacts break the contact so as to maintain a long life for the main contacts.
3) Due to this action, the compressed gas is released and it extinguishes the arc.
SF-6 Interrupter Pole
Rated Voltage- 12KV
Rated Current- 1250/2500/3150A
Rated Frequency- 50Hz
Rated Short Time Withstand Current- 40KA
Rated Duration of Short Circuit- 3sec
Rated SF6 gas pressure at 20 deg C- 2.5bar
Operational Features :
1) During breaking of the contacts, the puff of gas extinguishes the arc when the circuit breaker is in the closed position.
2) Due to movement of the piston, the gas is compressed. Firstly, the main contacts open and then the arcing contacts break the contact so as to maintain a long life for the main contacts.
3) Due to this action, the compressed gas is released and it extinguishes the arc.
Inclusive of all taxes
You Save: 0