TurbiMax CRP Liquid Stable Reagents are designed for the quantitative determination of C-Reactive Protein (CRP) levels in serum or plasma samples using turbidimetric analysis. This highly sensitive and reliable testing solution is specifically engineered for use in clinical laboratories that require high-performance reagents for accurate CRP quantification. The reagents demonstrate exceptional stability and linearity across various sample concentrations, ensuring reproducible results and enhanced diagnostic accuracy. With a detection limit of less than 2 mg/L and no prozone effect detected up to 800 mg/L, TurbiMax CRP reagents are suitable for a wide range of CRP levels. The kit includes a diluent reagent (R1), a Turbi Latex Reagent (R2), and a CRP calibrator, making it an all-inclusive solution for laboratory professionals seeking high-quality CRP testing solutions.
Key Features
Features | Description |
---|---|
Linearity Limit | Up to 100 mg/L, can be adjusted by dilution if samples exceed this limit. |
Detection Limit | Values less than 2 mg/L provide non-reproducible results. |
Prozone Effect | No prozone effect detected at concentrations up to 800 mg/L. |
Kit Composition | Includes 2*20ml Diluent Reagent (R1), 10ml Turbi Latex Reagent (R2), and 0.3ml CRP Calibrator. |
Ease of Use | Designed for simple preparation and application in clinical settings. |
Attributes | Description |
---|---|
In Vitro Diagnostic Use | Yes |
Testing Method | Turbidimetric / Immunoturbidometric |
Sample Type | Serum or plasma |
Storage Conditions | Store at 2-8°C. |
Shelf Life | 12 months from the date of manufacture. |
*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.
Country Of Origin: India
PERFORMANCE CHARACTERISTICS 1. Linearity limit: Up to 100 mg/L, under the described assay conditions. Samples with higher concentrations should be diluted 1/5 in saline (10 parts serum sample + 40 parts saline ex: 10μl serum sample+40 μl saline) and retested again and the results should be multiplied by 5.The linearity limit depends on the sample / reagent ratio, as well as the analyzer used. It will be higher by decreasing the sample volume, although the sensitivity of the test will be proportionally decreased. 2. Detection limit: Values less than 2 mg/Lgive non-reproducible results. 3. Prozone effect: No prozone effect was detected upon 800 mg/L.
TURBIMAX CRP
(Turbilatex /Immunoturbidometric)
1. Diluent Reagent (R1) = 2*20ml
2. Turbi Latex Reagent (R2) = 10ml
3. CRP Calibrator = 0.3ml