Type Of Protection: Ex E, Ex N, Ex P, Ex D, Ex De Power Range: Up To 25Mw Frame Size: Up To 1700 Number Of Poles: All Ingress Protection: Ip 55 And Higher Temperature Class: 155 (F), 180 (H) Method Of Cooling: Tefc, Tewjc, Cacw
Type Of Protection: Safe Area Power Range: Up To 13.2Mw Frame Size: 355&Nbsp;To 1120 Number Of Poles: 2, 4, 6 And More Ingress Protection: Ip 23, Ip 55 Temperature Class: 155 (F) Method Of Cooling: Caca, Cacw, Odp
Type Of Protection: Safe Area, Ex D, Ex N, Ex P Power Range: 20Kw To 25Mw Frame Size: 225-1000 And Above Number Of Poles: 2, 4 Ingress Protection: Up To 56 Temperature Class: F / H Method Of Cooling: Tefc, Caca, Cacw, Open Vent, Tewj
Type Of Protection: On Request Power Range: Up To 25Mw Frame Size: Up To 1400 Number Of Poles: To Suit Ingress Protection: Ip 23, Ip 55 Temperature Class: 155 (F), 180 (H) Method Of Cooling: Caca, Cacw And Special&Nbsp;Cooling&Nbsp;
Type Of Protection: Safe Area Power Range: Up To 2000 Kw Frame Size: Up To 900 Number Of Poles: 4-20 Ingress Protection: 55 Or Higher For Sub-Sea Temperature Class: 155 (F), 180&Nbsp;(H) Method Of Cooling: Caca / Cacw/ Tewjc
Type Of Protection: Safe Area Power Range: Up To 30 Mva Number Of Poles: 4-24 Ingress Protection: Ip 56 Temperature Class: F Method Of Cooling: On Demand
Type Of Protection: Safe Area Power Range: Up To 10Mw Frame Size: Up To 1700 Number Of Poles: 4 Ingress Protection: Up To 56 Temperature Class: F Method Of Cooling: Caca / Cacw / Tefc
Type Of Protection: Safe Area Power Range: Up To 10Mw Frame Size: Up To 1000 Number Of Poles: 2, 4, 6, 8 And More Ingress Protection: Ip 23, Ip 55 Temperature Class: 155 (F) Method Of Cooling: Tefc / Tewjc / Cacw / Caca / Odp
Motors For Circular Saws And Wood Working Water-Cooled Special Motors Exciters For Permanent Magnets Exciters For Synchronous Machines Nuclear Power Motors Military Defence Motors Built-In Motors Motors For Ethylene Reactors Drilling Motors
Type Of Protection: Ex D 1M Power Range: 200Kw To 2Mw Frame Size: Up To 630 Number Of Poles: 4 Ingress Protection: Ip56 Temperature Class: H Method Of Cooling: Tewjc
Power Range: As Per Request Frame Size: N/A Number Of Poles: Any Ingress Protection: N/A Temperature Class: F / H Method Of Cooling: N/A
Power Range: On Request Frame Size: On Request Number Of Poles: On Request Ingress Protection: On Request Temperature Class: 155 (F) Method Of Cooling: On Request
Type Of Protection: Safe Area Power Range: Up To 1Mw Frame Size: N/A - Equivalent 560 Number Of Poles: 12,16 Ingress Protection: Up To Ip55 Temperature Class: F / H Method Of Cooling: Tefc / Open Ventilated
Type Of Protection: Safe Area Power Range: 200 - 9.000 Kw Frame Size: 355 - 1120 Number Of Poles: 2 - 12 Ingress Protection: Ip55 Temperature Class: B Method Of Cooling: Ic01, Ic511, Ic611, Ic81W Options: Im B3, Im V1
Type Of Protection: Safe Area Power Range: 0.09 To 15Kw Frame Size: Up To 355 Number Of Poles: 4 Ingress Protection: Ip55 Temperature Class: F Method Of Cooling: Tefc
Type Of Protection: N/A Power Range: 0.11 To 2.2Kw Frame Size: N/A Number Of Poles: 4 Ingress Protection: N/A Temperature Class: F Method Of Cooling: N/A
Type Of Protection: Safe Area Power Range: Special Design - Upon Request Frame Size: Special Design - Upon Request Ingress Protection: Ip 67 Temperature Class: F / H Method Of Cooling: N/A
Type Of Protection: Safe Area Power Range: Special Design - Upon Request Frame Size: Special Design - Upon Request Ingress Protection: Ip 67 Temperature Class: 155 (F), 180 (H) Method Of Cooling: N/A
Type Of Protection: Safe Area - 200C, 400C, 600C Power Range: Up To 1000 Kw Frame Size: 80-500 Number Of Poles: 4 Ingress Protection: Up To 56 Temperature Class: 155 (F), 180 (H) Method Of Cooling: Tefc
Suction Blowers With Radial And Axial Fan Complete Motor System Including Mounting, Impeller And Housing. Customized Solution For Aggressive Environments And High Ambient Temperatures.
Type Of Protection: Safe Area Power Range: Up To 4Mw Frame Size: N/A Number Of Poles: All Ingress Protection: Up To Ip56 Temperature Class: F Method Of Cooling: Tefc / Tewjc
Type Of Protection: Safe Area Power Range: 0.07-90Kw Frame Size: 80-280 Number Of Poles: 4 Ingress Protection: 55 Temperature Class: F Method Of Cooling: Tefc
Series:3ZK, 4ZK, 5ZK Voltages:200-1.100V line and inverter operation Frame size:355 - 500 Frame construction: Fabricated steel and cast iron Power output: 375 - 1.320kW Degree of protection: IP55, IP56, IP65, IP66 Mounting arrangments: B3, B5, V1 Temperature class: 155 (F) according to 130 (B) or 180 (H) according to 155 (F) Efficiency class: non classified Cooling method: IC411 Number of poles: 2,4, 6, 8, 10 Certificates: CE
Series: ZP Voltages: 380 - 690V Frame size: 160 - 400 Frame construction: Fabricated steel and cast iron Power output: 7,5 - 500 kW Degree of protection: IP55 Mounting arrangments: B3, B5, V1 Temperature class: 155 (F) according to 130 (B) or 180 (H) according to 155 (F) Efficiency class: non classified Cooling method: IC411 Number of poles: 4, 6, 8, 10 Certificates: CE
Series:3ZK, 4ZK, 5ZK Voltages:200-1.100V line and inverter operation Frame size:315 - 560 Frame construction: Fabricated steel and cast iron Power output: 375 - 1.320kW Degree of protection: IP55, IP56, IP65, IP66 Mounting arrangments: B3, B5, V5, V6, V1, B35 Temperature class: 155 (F) according to 130 (B) or 180 (H) according to 155 (F) Efficiency class: IE3 Cooling method:IC411, IC410, IC416, IC418 Number of poles: 2,4, 6, 8, 10 Certificates: CE
Series:A, L and N Voltages:115-230V Frame size:56 - 112 Frame construction: Aluminium Power output:0,06 - 4 kW Degree of protection: IP55, IP56, IP65, IP66 Mounting arrangments: B3, V5, V6, B5, V1, V3, B35, B6, B7, B8, B30 Temperature class: 155 (F) according to 130 (B) or 180 (H) according to 155 (F) Efficiency class:non classified or IE2 Cooling method:IC411, IC410, IC416, IC418 Number of poles: 2,4, 6, 8 Certificates: CE
Series:w Voltages:200-690V line and inverter operation Frame size:63 - 355 Frame construction:Aluminium and Cast iron Power output:0,06 - 4 kW Degree of protection: IP55, IP56, IP65, IP66 Mounting arrangments: B3, V5, V6, B5, V1, V3, B35, B6, B7, B8, B30 Temperature class: 155 (F) according to 130 (B) or 180 (H) according to 155 (F) Efficiency class:IE3, IE4 Cooling method:IC411, IC410, IC416, IC418 Number of poles: 2,4, 6, 8 Certificates: CE
Series:KN Voltages:200-690V line and inverter operation Frame size:250 - 400 Frame construction:Cast iron Power output:37 - 1.300 kW Degree of protection:IP23 Mounting arrangments:B3, V5, V6, B5, V1, V3, B35 Temperature class: 155 (F) according to 130 (B) or 180 (H) according to 155 (F) Efficiency class:IE3, IE4 Cooling method:IC01, IC06 Number of poles: 2,4, 6, 8, 10 Certificates: CE
Series:A Voltages:200-690V line and inverter operation Frame size:56 - 280 Frame construction:Aluminium and Cast iron Power output:0,06 - 90kW Degree of protection:IP55, IP56, IP65, IP66 Mounting arrangments:B3, V5, V6, B5, V1, V3, B35 Temperature class: 155 (F) according to 130 (B) or 180 (H) according to 155 (F) Efficiency class:IE2, IE3 Cooling method:IC411, IC410, IC416, IC418 Number of poles: 2,4, 6, 8, 10 Certificates: CE
Series:WE3 Voltages:200-690V line and inverter operation Frame size:56 - 355 Frame construction:Aluminium and Cast iron Power output:0,06 - 90kW Degree of protection:IP55, IP56, IP65, IP66 Mounting arrangments:B3, V5, V6, B5, V1, V3, B35 Temperature class: 155 (F) according to 130 (B) or 180 (H) according to 155 (F) Efficiency class:IE3 Cooling method:IC411, IC410, IC416, IC418 Number of poles: 2,4, 6, 8, 10 Certificates: CE
Series:W, WP Voltages:200-690V line and inverter operation Frame size:80 - 355 Frame construction:Cast iron Power output:0,75 - 315kW Degree of protection:IP55, IP56, IP65, IP66 Mounting arrangments:B3, V5, V6, B5, V1, V3, B35 Temperature class: 155 (F) according to 130 (B) or 180 (H) according to 155 (F) Efficiency class:IE3 Cooling method:IC411, IC410, IC416, IC418 Number of poles: 2,4, 6, 8 Certificates: ATEX, IEC-EX
Series:W Voltages:200-690V line operation Frame size:80 - 355 Frame construction:Cast iron Power output:0,75 - 315kW Degree of protection:IP55, IP56, IP65, IP66 Mounting arrangments:B3, V5, V6, B5, V1, V3, B35 Temperature class: 155 (F) according to 130 (B) or 180 (H) according to 155 (F) Efficiency class:IE3 Cooling method:IC411, IC410, IC416, IC418 Number of poles: 2,4, 6, 8 Certificates: ATEX, IEC-EX
Series:CD; BD, BBD Voltages:200-690V line and inverter operation Frame size:63 - 500 Frame construction:Cast iron Power output:0,12 - 630kW Degree of protection:IP55, IP56, IP65, IP66 Mounting arrangments:B3, B5, V5, V6, V1, V18, B14, B35 Temperature class: 155 (F) according to 130 (B) or 180 (H) according to 155 (F) Efficiency class:IE3 Cooling method:IC411, IC410, IC416, IC418 Number of poles: 2 - 16 Certificates: ATEX, IEC-EX
Series:W-EF Voltages:200-690V line and inverter operation Frame size:90 - 315 Frame construction:Cast iron Power output:0,75 - 200kW Degree of protection:IP55, IP56, IP65, IP66 Mounting arrangments:B3, B5, V5, V6, V1, V18, B14, B35 Temperature class: 155 (F) according to 130 (B) or 180 (H) according to 155 (F) Efficiency class:IE3 Cooling method:IC411 Number of poles: 2 - 8 Certificates: ATEX, IEC-EX
Series:KD1, KD2 Ex protection level: Ex d IIB or C T4 Gb and Ex de IIB or C T4 Gb Voltages:200-690V line and inverter operation Frame size:63 - 500 Frame construction:Cast iron Power output:0,12 - 800kW Degree of protection:IP55, IP56, IP65, IP66 Mounting arrangments:B3, B5, V5, V6, V1, V18, B14, B35 Temperature class: 155 (F) according to 130 (B) or 180 (H) according to 155 (F) Efficiency class:IE3 Cooling method:IC411, IC410, IC416, IC418 Number of poles: 2 - 8 Certificates: ATEX, IEC-EX
Series:EC Vector Voltages:115, 208 or 230V 1 phase 50 or 60Hz Frame size:Special Frame construction:Steel Power output:1/4 - 1 Hp Degree of protection:IP20, IP55 Mounting arrangments:Specific mounting arrangement Efficiency class:IE4 Speed range:200 - 1800 rpm Certificates: UL, cUL, CE
Series:M Voltages:400V 50Hz Frame size:56 - 225 Frame construction:Aluminium, Cast iron Power output:0,25 - 100kW Degree of protection:IP55, IP56, IP65, IP66 Mounting arrangments:B3, B5, B14, V6, V5, B35, V1 Temperature class: 155 (F) according to 130 (B) Efficiency class:IE4 Cooling method:IC411, IC410, IC416, IC418 Speed range:0 - 3000 rpm Certificates: CE
Series:EC Voltages:380 - 480V 50 or 60HzFrame size:Special Frame construction:Steel Power output:3,7kW max Degree of protection:IP55 - IP66 Mounting arrangements:Specific mounting arrangement Efficiency class:IE4 Speed range:200 - 1800 rpm Certificates:UL, cUL, CE
Series:LN, DQ Voltages:400, 690V inverter operation Frame size:180- 400 Frame construction:Fabricated steelPower output:37 - 1300 kW Degree of protection:IP23 Mounting arrangements:B3, other Temperature class:155 (F) according to 130 (B) or 180 (H) according to 155 (F) Efficiency class:special Cooling method:IC01, IC06 Number of poles:2, 4, Certificates:CE Speed range:up to 15.000 min-1
Series:HB Voltages:200-1.100V line and inverter operationFrame size:315 - 560 Frame construction:Cast Iron Power output:375- 1.320kW Degree of protection:IP55, IP56, IP65, IP66 Mounting arrangements:B3, B5, V5, V6,V1, B35 Temperature class:155 (F) according to 130 (B) or 180 (H) according to 155 (F) Efficiency class:IE3 Cooling method:IC411, IC410, IC416, IC418 Number of poles:2, 4, 6, 8, 10 Certificates:CE
Certificates:CE Brand:Wolong Sever Voltages:380 - 690 VFrame size:180 - 355 Frame construction:Fabricated steel Power output:22-800 kW Degree of protection:IP23 Mounting arrangments:B3, V1 Temperature class:155 (F) according to 130 (B) Cooling method:IC01 Number of poles:2 - 16 Certificates:CE
Frame size:H56-H280 Power factor:0.7~0.9 Power range:0.12~90kW Insulation:F insulation B temperature rise Pole's:2?4?6, 8 Protection:IP55 as standard, IP65, 56, 66, 67 on request Voltages:230, 380, 400, 415, 440, 460, 480, 500, 690V Cooling:IC411 Frequencies:50Hz(60Hz ConnectionDuty:S1(S2, S3, S4-S9) Greasing:Motors up to frame 160 have bearings greased for life, 180 and up have regreasing facilities Speed:3000?1500?1000, 750 Housing:Aluminium available up to frame 200 Cast iron from frale 112
Series:2.BOK, 2.BPOK Voltages:200-690V line and inverter operationFrame size:200 - 450 Frame construction:Fabricated steel Power output:18,5 - 1.320kW Degree of protection:IP23 Mounting arrangements:B3, V5, V6, B5, V1, V3, B35 Temperature class:155 (F) according to 130 (B) or 180 (H) according to 155 (F) Efficiency class:IE2, IE3 Cooling method:IC01 Number of poles:2, 4, 6, 8, 10 Certificates:CE, RINA, GL, ABS, RMRS, etc
Series:BN Voltages:200-690V line and inverter operation Frame size:250 - 400 Frame construction:Cast iron Power output:37 - 1.300 kW Degree of protection:IP23 Mounting arrangements:B3, V5, V6, B5, V1, V3, B35 Temperature class:155 (F) according to 130 (B) or 180 (H) according to 155 (F) Efficiency class:IE2, IE3 Cooling method:IC01, IC06 Number of poles:2, 4, 6, 8, 10 Certificates:CE, ABS, BV, DNVGL, KR, LRS, RINA, RS
Series:BD Voltages:200-1.100V line and inverter operationFrame size:315 - 560 Frame construction:Cast Iron Power output:375- 1.320kW Degree of protection:IP55, IP56, IP65, IP66 Mounting arrangements:B3, B5, V5, V6,V1, B35 Temperature class:155 (F) according to 130 (B) or 180 (H) according to 155 (F) Efficiency class:IE3 Cooling method:IC411, IC410, IC416, IC418 Number of poles:2, 4, 6, 8, 10 Certificates:CE
Series:WEXF Temperature class:F400Frame size:80 -355 Voltages:220 - 400V line and inverter operation Power output:0,75- 355kW Frame construction:Cast iron Mounting arrangments:B3, B5, V5, V6,V1,V18, B14, B35, B30 Degree of protection:IP55, IP56, IP65, IP66 Number of poles:2 - 8 Insulation class:155 (F) or180 (H)Certificates:CE Cooling method:IC411, IC418 Efficiency class:IE3 Duty cycle:Dual purpose S1 or only S2 for emergency duty
Series:W, WP Temperature class:F200, F250, F300, F400Frame size:80 -355 Voltages:220 - 690V line and inverter operation Power output:0,75- 355kW Frame construction:Cast iron Mounting arrangments:B3, B5, V5, V6,V1,V18, B14, B35, B30 Degree of protection:IP55, IP56, IP65, IP66Number of poles:2 - 8 Insulation class:155 (F) or180 (H)Certificates:CE Cooling method:IC411, IC418 Efficiency class:Not classified, IE2, IE3 Duty cycle:Dual purpose S1 or only S2 for emergency duty
Series XSD Ultra,XSD Ultra 841,XSD Ultra 661 Voltages 230 - 575V line and inverter operation Frame size 143 - 449 Frame construction Cast iron Power output 1- 300 Hp Nema design A or B Mounting arrangements Foot, C-face, D-flange Temperature class Class F insulation Efficiency class NEMA Premium Cooling method TEFC, TENV, TEAO Number of poles 2, 4, 6 Certificates NEMA, UL, CSA, IEEE 45, 841, 112B, and GM 7E-TA Service factor 1.15 Balance and vibration ISO 1940 Grade 1, NEMA grade A